The Digital IO / Jog Control window lets you force Digital Inputs and Digital Outputs ON and OFF from the software. Forcing DIs is very helpful when testing servo functionality. Forcing DOs is very handy when testing field devices attached to the servo outputs. The DIs/DOs will return to normal function after this window is closed unless the “Remain the DI/O control status when this window is closed” checkbox is selected. Selecting the “Edit DI/O Item” checkbox will allow the user to change each of the DI and DO function assignments and configure for NO or NC operation. See Setting the Digital IO for more details.
This window also provides an easy way to jog the motor from the software. Simply enable the drive (from the screen if the DIs are not wired yet), enter a jog speed, and press the left or right arrow button to jog the motor. See Jog Control for more details.
For details on configuring the digital input and output settings, see Setting the Digital IO.
For details on using the Jog function, see Jog Control.