XG5000 Project Creation and Configuration
Follow the steps below to create and configure a project in XG5000 for use with an L7P servo system.
Step | Action |
---|---|
1 |
Open XG5000 and select Project è New Project.
|
2 |
Enter a name in the Project name field and select the CPU series of your XEM CPU from the CPU Series drop-down. Press OK to create the new project.
|
3 |
Double-click on LSPLC [B0S0 Internal Cnet] to configure the XEM CPU’s built-in RS-485 port.
|
4 |
Change the Baud Rate of CH 2 to 19200. Change the Operation Mode of CH 2 to Use P2P. Press OK when done.
|
5 |
Right-click on LSPLC [B0S0 Internal Cnet] and select Add ItemèP2P Communication.
|
6 |
Select 01 and press OK.
|
7 |
Under P2P 01(Internal), double-click P2P Channel.
|
8 |
Select Modbus RTU client for Channel 2. Press OK when done.
|
9 |
Press Yes to continue since no blocks have been created yet.
|
10 |
Double-click on Global/Direct Variables. This will allow you to create the variables for SV_ON, START, and ISEL0 – ISEL5.
|
11 |
Create Global Variables like the ones shown below.
|
12 |
Under P2P 01(Internal), double-click P2P Block.
|
13 |
Create the Modbus RTU Client blocks shown below.
|
14 |
Save the project. XG5000 Example Code for L7C shows some sample code that uses these global variables. |
LP215-4